Zemrex EMI shielding components for enclosure apertures
Wavetame Zemrex EMI shielding materials
Shield the Aperture

Why Do Windows & Vents Need Special EMI Treatment?

Every opening in a conductive enclosure can weaken the shielding boundary. Ventilation openings are needed to move air, and windows are needed to provide visual access, but both interrupt the otherwise continuous conductive surface. A shielded vent or screened window introduces a conductive structure across the aperture so airflow or visibility can be retained while the opening is electrically integrated into the enclosure. The conductive insert alone is only part of the design. The surrounding frame, bus-bar, gasket, surface finish and mounting method must all maintain reliable electrical contact with the enclosure.
Ventilation Aluminium honeycomb panels provide airflow while maintaining an RF shielding structure.
Visibility Fine conductive mesh can be integrated into transparent polycarbonate or acrylic windows.
Electrical Integration Frames, bus-bars and gaskets complete the conductive path into the enclosure.

Typical aperture requirements include:

  • Cooling airflow through an electronics enclosure.
  • Visual access to displays or indicators.
  • Maintaining shielding around a large opening.
  • Environmental sealing around the aperture perimeter.
  • Corrosion protection of the frame and enclosure interface.
  • Prototype or temporary screened-window requirements.
Two Different Aperture Problems

Shielded Vents vs Shielded Windows

Both products preserve shielding across an enclosure opening, but they solve very different functional requirements.

Airflow

Zemrex® Shielded Vents

Aluminium honeycomb sheet contained in an extruded aluminium frame allows cooling airflow through the enclosure while providing a conductive RF shielding structure. Vents can be manufactured to suit a wide range of aperture sizes, finished for corrosion protection or cosmetic requirements and supplied with a suitable sealing gasket.
Visibility

Zemrex® Shielded Windows

Fine conductive metal mesh can be laminated or cast into transparent polycarbonate or acrylic to provide a screened visual viewport. A suitably designed bus-bar and gasket arrangement electrically connects the conductive mesh into the enclosure around the window perimeter.
Zemrex® Shielded Vents

Aluminium Honeycomb Ventilation Panels

Wavetame’s shielded vents use aluminium honeycomb sheet contained in an extruded aluminium frame. The honeycomb allows air to pass through the aperture while presenting a conductive cellular structure to electromagnetic energy.

Vent assemblies can be manufactured to suit most aperture requirements and finished for corrosion protection or appearance using paint, electroplating or chemical surface conversion.

Honeycomb Core Aluminium honeycomb creates the conductive ventilating structure.
Aluminium Frame Extruded frame provides a robust mounting perimeter and electrical interface.
Surface Finishes Paint, electroplating or chemical surface conversion available to suit protection and appearance.
Sealing Gasket A suitable gasket can be supplied where the vent perimeter also requires sealing.
Vent Selection

Airflow, Shielding & Pressure Drop Must Be Balanced

A shielded vent has to satisfy both the thermal and EMC requirements of the enclosure. The opening must allow enough cooling air while the conductive honeycomb and frame provide the required shielding interface.

Final vent geometry should therefore be reviewed alongside required aperture size, airflow, fan arrangement, enclosure construction, operating environment and any specified shielding-performance requirement.

Useful vent information includes:

  • Required aperture width and height.
  • Available mounting and flange area.
  • Cooling airflow requirement.
  • Fan size and position, where applicable.
  • Enclosure material and surface finish.
  • Environmental sealing requirement.
  • Required corrosion-protection finish.
  • EMI/RFI performance requirement or governing specification.

Screened window construction

  • Fine conductive metal mesh.
  • Transparent polycarbonate or acrylic.
  • Mesh laminated or cast into the transparent substrate.
  • Conductive bus-bar around the perimeter.
  • Suitable gasket arrangement into the enclosure.
  • Custom window geometry to suit the application.
Zemrex® Shielded Windows

Conductive Mesh Integrated into Transparent Windows

Where operators need to see through an otherwise shielded enclosure, Wavetame can provide screened windows using fine conductive metal mesh laminated or cast into transparent polycarbonate or acrylic.

The conductive mesh must then be electrically connected around the window perimeter. A suitably designed bus-bar and gasket arrangement creates that path between the embedded mesh and the surrounding enclosure.

Window Selection

Optical Performance & Shielding Are a Trade-Off

A screened window must remain usable as a visual aperture while introducing enough conductive structure to satisfy the shielding requirement. Mesh type, optical clarity and electrical termination therefore need to be considered together.

01 / Optical

Define the Viewing Requirement

Consider display readability, viewing distance, lighting and how much mesh visibility is acceptable.
02 / Electrical

Terminate the Mesh Properly

The embedded conductive mesh must connect reliably through the bus-bar and gasket into the enclosure shielding path.
03 / Mechanical

Choose the Transparent Substrate

Polycarbonate or acrylic can be selected around the mechanical, environmental and optical needs of the application.
Zemrex® CCP

Clear Conductive Polyester for Prototype & Temporary Windows

Wavetame also offers Zemrex® CCP clear conductive polyester as a practical solution for temporary or prototype shielded-window applications.

The material can be cut to size with scissors and installed using conductive foil tape, making it useful where a quick screened aperture is needed before committing to a fully engineered laminated or cast window.

Handle CCP carefullyWavetame specifically notes that the material requires careful handling. It is best treated as a temporary or prototype solution rather than assumed to be equivalent to a permanent engineered shielded window.
Prototype Friendly Useful for development, evaluation and temporary screened apertures.
Cut to Size Can be trimmed with scissors for rapid installation.
Conductive Foil Tape Can be fitted into place using conductive foil tape.
Application Comparison

Which Aperture Treatment Fits the Requirement?

Requirement Typical solution Key points to review
Cooling airflow through the enclosure Aluminium honeycomb shielded vent Aperture size, airflow, pressure drop, shielding requirement, frame finish and sealing.
Permanent visual viewport Mesh-laminated / mesh-cast polycarbonate or acrylic window Optical clarity, mesh construction, bus-bar, gasket and mechanical substrate.
Temporary or prototype visual screening Zemrex® CCP clear conductive polyester Careful handling, conductive tape termination and suitability for temporary use.
Aperture also requires environmental sealing Vent or window with suitable perimeter gasket Gasket material, compression, enclosure finish and complete sealing path.
Electrical Integration

The Aperture Insert Must Bond Back into the Enclosure

A conductive honeycomb or metal mesh cannot provide useful enclosure shielding if it is electrically isolated from the surrounding housing. The mounting perimeter therefore needs a deliberate conductive path.

For windows, this is handled through the bus-bar and gasket arrangement. For vents, the aluminium frame and its interface with the enclosure perform the equivalent role. Surface coatings, corrosion protection and mounting hardware should all preserve that intended electrical contact.

Check the complete aperture interface

  • Conductive insert or mesh.
  • Frame or perimeter bus-bar.
  • Shielding / sealing gasket.
  • Enclosure contact surface.
  • Fastener spacing and mechanical pressure.
  • Corrosion-protection system.
Corrosion Protection

Surface Finish Must Protect Without Breaking the Shielding Path

Shielded vents are aluminium assemblies and may be exposed to challenging environmental conditions. Wavetame therefore offers paint, electroplating and chemical surface conversion finishes for corrosion protection and cosmetic requirements.

As with any EMI interface, the protective finish must be considered alongside electrical contact. A finish that electrically isolates the vent frame from the enclosure can compromise the intended shielding path.

Paint Available where cosmetic or environmental protection requires a painted finish.
Electroplating Metallic surface treatment option for appropriate shielding and corrosion requirements.
Chemical Conversion Conversion finish available for aluminium vent assemblies.
Custom to the Aperture

Windows & Vents Are Application-Specific Components

Aperture dimensions, optical requirements, cooling demand, enclosure finish and shielding specification vary considerably between applications, so Wavetame manufactures and supplies these products against the actual requirement rather than treating them as one universal catalogue size.

01 / Aperture

Define the Geometry

Provide the opening dimensions, available flange and any mounting-hole arrangement around the aperture.
02 / Function

Define Airflow or Visibility

Tell us whether the aperture is primarily for cooling airflow, viewing access or both as part of a larger enclosure design.
03 / EMC

Define the Shielding Requirement

Provide the required performance, frequency range or governing customer / programme specification where known.
Legacy Zemrex® References

Shielded Windows, Vents & CCP

Historic Warth International documentation may refer generally to Zemrex® shielded windows and vents or specifically to CCP conductive coated polyester.

Zemrex® Shielded Windows & Vents Historic Zemrex® product family covering screened visual windows and shielded ventilation apertures.
Zemrex® CCP Conductive coated polyester. Current Wavetame literature also identifies clear CCP conductive polyester for temporary or prototype shielded-window applications.
If you have an old Warth window, vent or CCP part number, send the complete reference, drawing or surviving component details to Wavetame. We can review the original requirement against current construction options.
Application Review

What Should I Send When Asking for a Shielded Window or Vent?

  • Aperture dimensions or enclosure drawing.
  • Required airflow or visual opening size.
  • Enclosure material and surface finish.
  • Required shielding performance or governing specification.
  • Environmental sealing requirement.
  • Required corrosion-protection or cosmetic finish.
  • For windows, preferred transparent substrate if already specified.
  • Any Warth / Zemrex® legacy reference or existing sample.
Have an Aperture to Shield?

Send Wavetame the Drawing or Dimensions

We can review the airflow, visibility, shielding and environmental requirements together and identify an appropriate window or vent construction.
Send an Aperture Enquiry
Related Information

Continue Exploring Zemrex® Shielding

Product Family

Conductive Fabrics, Foams & Meshes

Explore conductive textiles, foam profiles and open-weave meshes used across shielding and window applications.

Explore Fabrics & Meshes
Product Family

Shielding Hardware

Earthing straps, conductive foils, fingerstock and screened cable glands for completing the enclosure shielding path.

Explore Shielding Hardware
Engineering Guide

How to Choose an EMI/RFI Shielding Gasket

Understand the joint-design principles that also apply to window and vent perimeter interfaces.

Read the Guide
Need Airflow or Visibility Without Losing Shielding?

Send Us the Aperture, Enclosure & EMC Requirement

Wavetame can review the aperture dimensions, airflow or optical requirement, enclosure materials, environmental sealing and shielding specification to identify a suitable Zemrex® window or vent construction.